XJ-D621 8S 24V 100A 150A BMS for LifePO4 Li-ion Sodium-ion Battery BMS
XJ-D621 8S 24V 100A 150A BMS, with balance NTC, application in LifePO4/Li-ion/Sodium-ion battery.
|
Product Name
|
8S 24V BMS battery management system
|
|
Size
|
Length 161mm * Width 65mm * Thickness 10mm
|
|
Series
|
8S
|
|
Current
|
100A-150A
|
|
Voltage
|
24V
|
|
Cell Type
|
LFP/NCM/Sodium-Ion/Li-ion Battery
|
|
Function
|
Over charge protection, Over discharge protection, Over current protection, Short-circuit protection, Balance function, Temperature sensor function, Electrostatic protection, Dust Protection, Moisture Protection
|
|
Warranty
|
24 Months
|
|
Item (the spec of 8S 100A NMC)
|
Min
|
Typical
|
Max
|
Unit
|
|
Battery pack charging voltage
|
28.8
|
V
|
||
|
Charging MOS withstand voltage
|
100
|
V
|
||
|
Discharging MOS withstand voltage
|
100
|
V
|
||
|
Single cell overcharge detection voltage
|
3.625
|
3.65
|
3.675
|
V
|
|
Overcharge recovery voltage
|
3.5
|
3.55
|
3.6
|
V
|
|
Overcharge detection delay
|
500
|
1000
|
1500
|
mS
|
|
Single cell over-discharge detection voltage
|
2.2
|
2.3
|
2.4
|
V
|
|
Over-discharge recovery voltage
|
2.6
|
2.7
|
2.8
|
V
|
|
Over-discharge detection delay
|
500
|
1000
|
1500
|
mS
|
|
Battery pack continuous discharge current
|
100
|
A
|
||
|
Battery pack continuous charging current
|
100
|
A
|
||
|
Discharge overcurrent protection 1
|
280
|
300
|
320
|
A
|
|
Overcurrent protection delay 1
|
500
|
1000
|
1500
|
mS
|
|
Discharge overcurrent protection 2
|
530
|
560
|
590
|
A
|
|
Overcurrent protection delay 2
|
50
|
100
|
150
|
mS
|
|
Charging overcurrent protection
|
140
|
150
|
160
|
A
|
|
Overcurrent protection delay
|
500
|
1000
|
1500
|
mS
|
|
Self-consumption
|
60
|
uA
|
||
|
Battery equalization turn-on voltage
|
3.475
|
3.5
|
3.525
|
V
|
|
Battery equalization current
|
30
|
-
|
60
|
mA
|
|
Charging high temperature protection temperature
|
50
|
55
|
60
|
℃
|
|
Charging high temperature recovery temperature
|
45
|
50
|
55
|
℃
|
|
Discharge high temperature protection temperature
|
65
|
70
|
75
|
℃
|
|
Discharge high temperature recovery temperature
|
55
|
60
|
65
|
℃
|
|
Charging low temperature protection temperature
|
-5
|
0
|
5
|
℃
|
|
Charging low temperature recovery temperature
|
0
|
5
|
10
|
℃
|
|
Discharge low temperature protection temperature
|
-25
|
-20
|
-15
|
℃
|
|
Discharge low temperature recovery temperature
|
-20
|
-15
|
-10
|
℃
|
|
Temperature protection delay
|
3
|
S
|
||
|
Output short circuit/over-discharge/overcurrent protection recovery
|
Automatic recovery after removing load following short circuit/over-discharge/over-current protection
|
|||
|
Short circuit protection delay
|
160
|
300
|
600
|
uS
|
|
Normal operating state B-to-P- internal resistance
|
30
|
mΩ
|
||
|
Continuous 100A output current maximum temperature rise
|
45
|
℃
|
||