Product Name
|
4S 12V 40A Motorcycle Starting BMS
|
|
Size
|
Length 65mm * Width 60mm * Thickness 4mm
|
|
Series
|
4S
|
|
Current
|
40A
|
|
Voltage
|
12.8V/14.8V
|
|
Cell Type
|
LFP 3.2V/NMC 3.7V/Sodium-ion battery
|
|
Function
|
Balance, NTC
|
|
Function
|
Over charge protection, Over discharge protection, Over current protection, Short-circuit protection, Balance function, Temperature sensor function, Electrostatic protection, Dust Protection, Moisture Protection
|
|
Warranty
|
24 Months
|
|
Notice: This BMS does not support use of LifePO4 and NMC battery in the same circuit board, please inform us whether it is LFP battery or NMC battery before ordering.
|
|
Specification:
| Test Items | Minimum | Typical | Maximum | Unit |
| Battery pack charging voltage | 14.8 | V | ||
| Charging MOS withstand voltage | 40 | V | ||
| Discharge MOS withstand voltage | 40 | V | ||
| Single cell overcharge detection voltage | 3.6 | 3.65 | 3.7 | V |
| Overcharge recovery voltage | 3.5 | 3.55 | 3.6 | V |
| Overcharge detection delay | 500 | 1000 | 1500 | mS |
| Single cell overdischarge detection voltage | 2.2 | 2.3 | 2.4 | V |
| Over discharge voltage | 2.6 | 2.7 | 2.8 | V |
| Over discharge detection dela | 500 | 1000 | 1500 | mS |
| The battery pack continues to discharge current | 40 | A | ||
| Battery pack keeps charging current | 40 | A | ||
| Self-consumption | 20 | 50 | uA | |
| Equalizing starting voltage | 3.525 | 3.55 | 3.575 | V |
| Equalizing current | 40 | - | 80 | mA |
| Output short-circuit/overdischarge/overcurrent protection recovery | After short circuit/overdischarge/overcurrent protection is removed, the load automatically recovers | |||
| Short-circuit protection delay | 160 | 200 | 240 | uS |
| Normal operating condition B- to P- internal resistance | 30 | mΩ | ||
| Maximum temperature rise of continuous 40A output current | 50 | ℃ | ||