XJ-D170 BMS 5S 21V 10A Common Port Passive Balance NTC Temperature Sensors
XJ-D170 5S 21V 5A/10A BMS, common port, passive balance, NTC.
|
Product Name
|
5S battery management system BMS
|
|
Size
|
Length 90mm*Width 18mm*Thickness 5mm
|
|
Series
|
5S
|
|
Current
|
5A/10A
|
|
Cell Type
|
LFP/NCM/Lithium
|
|
Function
|
Same Port/NTC/Balance
|
|
Protection
|
Over charge protection, Over discharge protection, Over current protection, Short-circuit protection, Balance function, Temperature sensor function, Electrostatic protection, Dust Protection, Moisture Protection
|
|
Warranty
|
24 Months
|
| Item | Symbol | Inspection standard | Unit | |||
| Min | Typical | Max | ||||
| Overcharge protection | Overcharge detection voltage | VOVP | 4.2 | 4.25 | 4.3 | V |
| Overcharge protection delay time | tOVP | 500 | 1000 | 1500 | ms | |
| Overcharge discharge voltage | VOVR | 4.1 | 4.15 | 4.2 | V | |
| Over-discharge protection | Over-discharge detection voltage | VUVP | 2.6 | 2.7 | 2.8 | V |
| Overdischarge protection delay time | tUVP | 500 | 1000 | 1500 | ms | |
| Over-discharge discharge voltage | VUVR | 2.9 | 3 | 3.1 | V | |
| Overcurrent protection | Overcurrent 1 detects voltage | VDOCP1 | 0.095 | 0.1 | 0.105 | V |
| Overcurrent protection current | IDP | 28 | 33 | 38 | A | |
| Detection delay time | tDOCP1 | 50 | 100 | 150 | ms | |
| Short-circuit protection | Detection delay time | TSHORT | 200 | 250 | 300 | μS |
| Conditions for lifting protection | Disconnect the external short-circuit load or charge and restore | |||||
| Equalize | Equalizing turn-on voltage | VBAL | 4.1 | 4.15 | 4.2 | V |
| Equalizing current | IBAL | 30 | 40 | 50 | mA | |
| Internal resistance | Main circuit on-state resistor | RDS | 50 | mΩ | ||
| Current consumption | It usually consumes current when in operation | IVCC-NOR | 50 | μA | ||
| Static current | It consumes current during hibernation | IVCC-PD | 10 | μA | ||
| Discharge | Sleep function | YES | ||||