Leave Your Message
XJ-D129 10S 42V 20A BMS Electric Scooters E-bikes Separate Port Charge 3A Discharge 20A
Hardware BMS

XJ-D129 10S 42V 20A BMS Electric Scooters E-bikes Separate Port Charge 3A Discharge 20A

This model XJ-D129 BMS, 10S 20A for electric scooters, e-bikes. Split port, charging 3A, discharging 20A, with NTC temperature sensor, over-short, over-discharge, over-voltage, and over-current protection. Suitable for LiFePO4, NMC, and Li-ion batteries. When the 20A discharge continues, the high temperature reaches 40℃.

  • Model XJ-D129
  • Series 10S
  • Current 20A
  • Voltage 42V
  • Cell Type NMC/LFP/Lithium
  • Function Over charge protection, Over discharge protection, Over current protection, Short-circuit protection, NTC Temperature sensor function, Electrostatic protection, Dust Protection, Moisture Protection
  • Warranty 24 Months
  • Board Size 297*34*5MM
  • OEM/ODM Acceptable
  • Application Electric scooters, E-bikes

10S 42V 20A BMS for electric scooters, e-bikes, with NTC temperature sensors, seperate port charge 3A discharge 20A

Model
XJ-D129
Series
10S
Charge Current
3A
Discharge Current
20A
Voltage
42V
Battery
LifePO4/NMC/Li-ion battery
Application
Electric Scooter/E-bikes
Warranty
2 Years
OEM&ODM
YES

Item (The spec of 10S 20A) Min Typical Max Unit
Battery pack charging voltage 42 42.5 V
The withstand voltage of the charging MOS 65 V
Discharge MOS withstand voltage value 65 V
Single-cell overcharge detection voltage 4.2 4.25 4.3 V
Overcharge recovery voltage 4 4.05 4.1 V
Overcharge detection delay 500 1000 1500 mS
Single-section overdischarge detection voltage 2.6 2.7 2.8 V
Overdischarge recovery voltage 2.9 3 3.1 V
Over-discharge detection delay 500 1000 1500 mS
Continuous discharge current of the battery pack 20 A
Continuous charging current of the battery pack 5 A
Discharge overcurrent protection 40 50 60 A
Overcurrent protection delay 500 1000 1500 mS
Self-consumption 30 40 uA
Equilibrium current / / / mA
Charging temperature protection 60±5℃.
Discharge temperature protection 80±5℃
Output short circuit/overdischarge/overcurrent protection recovery After short-circuit/overdischarge/overcurrent protection, the load is removed and it automatically recovers
Short-circuit protection delay 100 300 600 uS
Under normal working conditions, the internal resistance is B- to P- 30
Maximum temperature rise with a continuous output current of 20A 40

D129 10S 20A BMS (2).jpgD129 10S 20A BMS (3).jpgD129 10S 20A BMS (4).jpgD129 10S 20A BMS (5).jpgD129 10S 20A BMS (6).jpgD129 10S 20A BMS (7).jpg