Product Name
|
BMS battery management system
|
|
Size
|
Length 100mm*Width 60mm*Thickness 8mm
|
|
Series
|
4S~14S
|
|
Current
|
30A~50A
|
|
Voltage
|
12V~52V
|
|
Balance/NTC
|
Yes
|
|
Battery Cell Type
|
LifePO4/NMC/Sodium-Ion/Li-ion Battery
|
|
Function
|
Balance, NTC temperature sensor, same port or split port (optional)
|
|
Protection
|
Over charge protection, Over discharge protection, Over current protection, Short-circuit protection, Balance function, Temperature sensor function, Electrostatic protection, Dust Protection, Moisture Protection
|
|
Warranty
|
24 Months
|
|
Item
(The specification of 13S 50A NMC Battery) |
Min
|
Typical
|
Max
|
Unit
|
|
Battery Pack Charging Voltage
|
50.4
|
51.1
|
V
|
|
|
Charging MOSFET Voltage Rating
|
85
|
V
|
||
|
Discharging MOSFET Voltage Rating
|
85
|
V
|
||
|
Single Cell Overcharge Detection Voltage
|
3.6
|
3.65
|
3.7
|
V
|
|
Overcharge Recovery Voltage
|
3.5
|
3.55
|
3.6
|
V
|
|
Overcharge Detection Delay
|
500
|
1000
|
1500
|
mS
|
|
Single Cell Overdischarge Detection Voltage
|
2.2
|
2.3
|
2.4
|
V
|
|
Overdischarge Recovery Voltage
|
2.6
|
2.7
|
2.8
|
V
|
|
Overdischarge Detection Delay
|
500
|
1000
|
1500
|
mS
|
|
Battery Pack Continuous Discharge Current
|
40
|
A
|
||
|
Battery Pack Continuous Charge Current
|
40
|
A
|
||
|
Discharge Overcurrent Protection
|
100
|
120
|
140
|
A
|
|
Overcurrent Protection Delay
|
500
|
1000
|
1500
|
mS
|
|
Self-Consumption
|
30
|
50
|
uA
|
|
|
Balancing Current
|
55
|
70
|
80
|
mA
|
|
Charging Temperature Protection
|
High: 55±5°C, Low: -5±5°C
|
|||
|
Discharging Temperature Protection
|
High: 70±5°C, Low: -25±5°C
|
|||
|
Output Short-Circuit/Overdischarge/Overcurrent Protection Recovery
|
Automatically recovers after short-circuit/overdischarge/overcurrent protection when load is removed
|
|||
|
Short-Circuit Protection Delay
|
100
|
300
|
600
|
uS
|
|
Internal Resistance (B- to C- under normal operation)
|
30
|
mΩ
|
||
|
Maximum Temperature Rise at 40A Continuous Output Current
|
40
|
℃
|
||