Leave Your Message
XJ-D092 4S-14S 5A-20A BMS for LifePO4/NMC/Li-ion Battery with NTC Temp Sensors
Hardware BMS

XJ-D092 4S-14S 5A-20A BMS for LifePO4/NMC/Li-ion Battery with NTC Temp Sensors

This model is suitable for electric two-wheelers, supporting 4S-14S and 5A-20A, and can same-port and split-port, with support for LifePO4 and NMC batteries. 

  • Model XJ-D092
  • Battery Cell 4S~14S
  • Working Current 5A~20A
  • Cell Type LifePO4 / NMC /Li-ion
  • Size Length 80mm*Width 40mm*Thickness 6mm
  • Function Balance, NTC temperature sensors
  • Feature Over charge protection, Over discharge protection, Over current protection, Short-circuit protection, Balance function, Temperature sensor function, Electrostatic protection, Dust Protection, Moisture Protection
  • Warranty 24 Months

XJ-D092 4S-14S 5A-20A BMS for LifePO4/NMC/Li-ion Battery with NTC Temp Sensors

Product Name
4S~14S 5A~20A BMS battery management system
Size
Length 80mm*Width 40mm*Thickness 6mm
Series
4S~14S
Current
5A~20A
Cell Type
LifePO4 / NMC /Li-ion
Function
Balance, NTC temperature sensors
Function
Over charge protection, Over discharge protection, Over current protection, Short-circuit protection, Balance function,
Temperature sensor function, Electrostatic protection, Dust Protection, Moisture Protection
Warranty
24 Months




Parameter
(The specification of 11S 10A NMC battery BMS) 
Min
Typical
Max
Unit
Battery Pack Charge Voltage
39.8
40.1
V
Charge MOSFET Voltage Withstand Rating
65
V
Discharge MOSFET Voltage Withstand Rating
65
V
Single Cell Overcharge Detection Voltage
3.6
3.65
3.7
V
Overcharge Recovery Voltage
3.5
3.55
3.6
V
Overcharge Detection Delay
500
1000
1500
ms
Single Cell Overdischarge Detection Voltage
2.2
2.3
2.4
V
Overdischarge Recovery Voltage
2.6
2.7
2.8
V
Overdischarge Detection Delay
500
1000
1500
ms
Continuous Discharge Current
10
A
Continuous Charge Current
10
A
Discharge Overcurrent Protection
28
33
38
A
Overcurrent Protection Delay
500
1000
1500
ms
Standby Current Consumption
30
50
μA
Cell Balancing Current
55
70
80
mA
Charge Temperature Protection
High: 55±5°C, Low: -5±5°C
Discharge Temperature Protection
High: 70±5°C, Low: -25±5°C
Protection Recovery (SC/OVD/OCP)
Auto-recovery after fault clearance (load removal)
Short Circuit Protection Delay
100
300
600
μs
Internal Resistance (B- to C-)
40
Max Temperature Rise 10A Continuous
40
°C