Leave Your Message
XJ-D043 4S 15.4V 60A BMS Balance NTC LifePO4 NMC Li-ion Battery Management System
4S BMS

XJ-D043 4S 15.4V 60A BMS Balance NTC LifePO4 NMC Li-ion Battery Management System

This model XJ-D043, 4S 15.4V 60A, support 4-cell LifePO4/NMC (Li-ion) battery. With balance and NTC temperature sensors. The common port has a charge current and discharge current of 60A. Application to electric power tools, UPS portable power supplies...With overcharge/overdischarge/overcurrent/short-circuit protection.

  • Model XJ-D043
  • Series 4S
  • Current 60A
  • Voltage 15.4V
  • Cell Type NMC/LFP/Lithium
  • Function Over charge protection, Over discharge protection, Over current protection, Short-circuit protection, Electrostatic protection, Dust Protection, Moisture Protection, Balance and NTC
  • Warranty 24 Months
  • Board Size 103*51*11MM
  • OEM/ODM Acceptable
  • Application Electric power tools, UPS portable power supplies...

4S 15.4V 60A BMS, with balance NTC temperature sensors, for lifepo4 battery and li-ion battery.

Product Name

XJ-D043 4S 60A BMS

Size

103*51*11MM

Series

4S 

Current

60A

Cell Type

LifePO4/NMC (Li-ion) battery

Function

Over charge protection, Over discharge protection, Over current protection, Short-circuit protection, Balance function, NTC Temperature sensor function, Electrostatic protection, Dust Protection, Moisture Protection

Warranty

24 Months

Item Min Typical Max Unit
Battery pack charging voltage 15.4 15.5 V
The withstand voltage of the charging MOS 30 V
Discharge MOS withstand voltage value 30 V
Single-cell overcharge detection voltage 3.8 3.85 3.9 V
Overcharge recovery voltage 3.55 3.6 3.65 V
Overcharge detection delay 500 1000 1500 mS
Single-section overdischarge detection voltage 2.2 2.3 2.4 V
Overdischarge recovery voltage 2.4 2.5 2.6 V
Over-discharge detection delay 500 1000 1500 mS
Continuous discharge current of the battery pack 60 A
Continuous charging current of the battery pack 60 A
Discharge overcurrent protection 180 200 220 A
Overcurrent protection delay 5 10 20 mS
Self-consumption 30 50 uA
Equilibrium current 30 40 50 mA
Charging temperature protection 65±4℃.
Discharge temperature protection 65±4℃.
Output short circuit/overdischarge/overcurrent protection recovery After short-circuit/overdischarge/overcurrent protection, the load is removed and it automatically recovers
Short-circuit protection delay 100 300 600 uS
Under normal working conditions, the internal resistance is B- to P- 10
Maximum temperature rise with a continuous output current of 60A 40

D043 4S 60A BMS (2).jpgD043 4S 60A BMS (3).jpgD043 4S 60A BMS (4).jpgD043 4S 60A BMS (5).jpg