Leave Your Message
XJ-F002 Smart BMS: Industrial-Grade Battery Protection for EVs, AGVs, ESS & Mobility
NEW Product

XJ-F002 Smart BMS: Industrial-Grade Battery Protection for EVs, AGVs, ESS & Mobility

2025-08-12

Why Precision Bms Matters in the Lithium Era

As lithium batteries power global electrification, their risks—thermal runaway, fire, and explosion—demand uncompromising protection. XJ-F002 Intelligent BMS delivers military-grade safety for LFP, NMC, and Sodium-Ion (SIB) batteries, engineered by Xuanjing with 10+ years of BMS expertise.  

4 Game-Changing Advantages 

1. Multi-Chemistry Compatibility  

- Voltage/Current: 4S-20S Series | 50A-120A Continuous  

- Chemistry: LFP / NMC / SIB (Pre-configured per cell specs)  

2. Arctic-Ready Operation  

- -20℃ Heating Function: Ensures charging/discharging in extreme cold  

- 4-Channel NTC Monitoring: Real-time thermal protection  

3. Data-Driven Intelligence  

- 340+ Event Logs: Full historical data tracking (Storage IC adjustable)  

- Passive Balancing: Extends cycle life by 30% (Auto cell voltage correction)  

- Capacity Self-Learning: Achieves 95% SOC accuracy  

4. 3-Second Setup  

- Dual Control: Bluetooth App + 485/UART Interface  

- Zero Tools Needed: Modify parameters via smartphone  

factory setting.jpg

Engineer-Approved Applications  

Industry

Use Cases

Critical Notes

E-Mobility

E-bikes · Trikes · Forklifts

Current rating compliance

Industrial

AGVs · Yacht Power Systems

Waterproofing required

ESS

Off-grid Solar · Backup Power

No grid-tie/parallel support

Technical Deep Dive: How F002 Outperforms  

 Installation Protocol  

     Wrong wiring order = Permanent damage

     Step-by-Step:  

  1. Connect P- → B- → NTC probes → Comm wires → Cell taps (B0→B20 sequentially)  
  2. Secure all connectors with silicone glue (prevents oxidation)  
  3. Never omit ESD protection during installation  

F002 BMS (6).jpg

 Smart Power Management  

Mode

Trigger Condition

Power Consumption

Standby

No current/communication for 10s

<700μA

Shutdown

Cell voltage < threshold + no current

<20μA

Wake-up

Charging/discurrent/communication detected

-

  Port Definitions (Survival Guide)  

 

Port

Pinout

Function

B-

-

battery negative

P-

-

Charger/load negative

NTC

4 channels

External probes

BT

GND/TX/RX/VDD

Bluetooth module

485

A/B/GND/VDD

RS485 communication (Baud: 9600)

H+/H-

-

Heating pad terminals

3 Reasons Engineers Choose F002  

  1. Plug & Play ESS Integration  

            - Custom inverter protocol burning service (Provide your comm specs)  

  1. Maintenance Cost Slasher  

            - 340+ fault logs enable instant root-cause analysis  

  1. Unmatched Price-Performance  

            - 50% lower TCO vs. industrial competitors  

basic data.png

Critical FAQs (Avoid Costly Mistakes!)  

Q: Can I use F002 for grid-tied solar?  

→ ❌ No. Supports off-grid only. Never parallel!  

Q: How to configure sodium-ion batteries?  

→ Share cell specs at order placement. We pre-burn firmware.  

Q: Calibration trick for current sensing?  

→ Use a 10A load to match APP/actual current by adjusting the shunt value.  

If more customization, pls feel free to contact us.