XJ-D428 4S 12V 100A BMS, build-in 1A active balance






|
Type |
Specification |
|
(1) 4S 100A BMS with 1A active balance, |
Supports 4S Batteries. Battery Type: LFP/MNC
Dimension:140*65*12mm |
|
Function |
Test Items |
Specifications |
Unit |
|||
|
|
|
Min. |
Typ. |
Max. |
|
|
|
Operating Voltage |
Voltage Range |
8 |
-- |
35 |
V |
|
|
Operating Current |
Charging Current (Continuous) |
|
100 |
|
A |
|
|
|
|
|
100 |
|
A |
|
|
Charging Protection |
Charger Voltage (CC - CV) |
15.2±0.2 |
V |
|||
|
|
|
3.65 |
3.70 |
3.75 |
V |
|
|
|
|
700 |
1000 |
1300 |
mS |
|
|
Overcharge protection recovery voltage |
3.45 |
3.50 |
3.55 |
V |
|
|
Discharge protection |
Over discharge protection voltage |
1.95 |
2. 00 |
2. 05 |
V |
|
|
Over discharge protection delay time |
700 |
1000 |
1300 |
mxD |
|
|
Over discharge protection recovery voltage |
2.35 |
2.4 |
2.45 |
V |
|
Overcurrent protection |
Charging overcurrent protection value |
|
50 |
|
A |
|
|
Charge overcurrent delay |
700 |
1000 |
1300 |
mS |
|
|
Charge overcurrent release recovery conditions |
Built-in charging overcurrent protection |
|||
|
|
Discharge overcurrent 1 Protection current value |
400 |
450 |
500 |
A |
|
|
Discharge overcurrent 1 Protection delay |
700 |
1000 |
2000 |
mS |
|
|
Discharge overcurrent 2 Protection current value |
700 |
800 |
900 |
A |
|
|
Discharge overcurrent 2 Protection Delay |
350 |
500 |
1000 |
mS |
|
|
Discharge overcurrent protection recovery conditions |
Disconnect load or activate charging |
|||
|
Short circuit protection |
Short circuit protection delay time |
230 |
330 |
430 |
uS |
|
|
Short circuit protection recovery |
Remove the short circuit and disconnect the load |
|||
|
|
Short circuit current |
1200-2400A |
|||
|
Equalization function |
Balanced start voltage |
|
≧ 2.8V |
|
V |
|
|
Balanced opening pressure difference |
|
35 ± 5 MV |
|
mV |
|
|
Balanced mode |
Active balancing |
|||
|
|
Balance current |
65 |
/ |
1000 |
mA |
|
Temperature protection |
Charging high temperature protection value |
64 |
67 |
70 |
℃ |
|
|
Charging high temperature protection release value |
55 |
58 |
61 |
℃ |
|
|
Charging low temperature protection value |
-15 |
-10 |
-5 |
℃ |
|
|
Charging low temperature protection release value |
-3 |
0 |
3 |
℃ |
|
|
Discharge high temperature protection value |
75 |
80 |
85 |
℃ |
|
|
Discharge high temperature protection release value |
65 |
70 |
75 |
℃ |
|
|
Discharge low temperature protection value |
-35 |
-30 |
-25 |
℃ |
|
|
Discharge low temperature protection release value |
-25 |
-20 |
-15 |
℃ |
|
Internal resistance |
Discharge circuit internal resistance |
/ |
0.24 |
0.25 |
mR |
|
Self-consumption |
Working Mode |
|
|
50 |
uA |
|
|
Sleep Mode |
|
|
25 |
uA |
|
|
Sleep conditions and delay |
/ |
|||
|
Operating temperature |
Normal operating range |
- 40 |
|
105 |
℃ |
|
Storage temperature |
Humidity is less than 90%, |
-40 |
|
125 |
℃ |
|
Finished product size |
Length*Width*Height |
MAX : 140*65*12mm |
|||